Permit: T03CM05383

Parcel: 125042390


Addresses:

2130 E 2ND ST #01

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/15/2004 FRAMING Approved IVRS - Inspection :*
10/12/2004 FRAMING Partial Approval IVRS - Inspection :*/UNABLE TO LOCATE SIGN OFF SHEET
10/08/2004 FRAMING Partial Approval IVRS - Inspection :NO COMBUSTION AIR PROVIDED FOR WH
WATER LINE TOUCHING CAN LIGHT IN KITCHEN
FLEX DUCT TOUCHING WH FLUE
OK TO INSULATE EXCEPT AFFECTED AREAS
09/23/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) FIRESTOP INCOMPLETE FIREPLACE 2) FIREBLOCKS MISSING KITCHEN FURR DOWN 3) INSTALL DBL STUDS UNDER GIRDER TRUSSES 4) TEST DWV THROUGHOUT ROOF 5) STRAP PLUMBING, ELECTRIC THROUGHOUT 6) INSTALL COMB/RELIEF AND FLU H20 HEATER 7) REMOVE WIRES AWAY FROM FLUE PIPES 8) STOPPED INSPECTION 9) COMPLETE ALL TRADES AND RECALL