Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/30/2004 FRAMING Approved IVRS - Inspection :*
06/28/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) SUPPORT FURANCE PLATFORM OSB 2) KEEP PEX 6" FROM FURNACE FLUE 3) PUT IHA STRAPS AT DRYER DUCT STUD 2 X 6 4) INSTALL LAUNDRY FAN 5) COMB/RELIEF DUCTS, RELIEF DUCT TO BE 12" FROM CEILING 6) GARAGE BOTTOM PLATE SPLICE NEED A.B. TWO PLACES 7) INSULATE ALL DUCT SPLICES 8) REMOVE SOME CONCRETE AT N/E BATH TOP, LOOKS LIKE TUB IS LEAKING 9) EXHAUST DUCTS TO ROOF 11) PEX 12" TO CAN LIGHT NORTH BEDROOM AND HALL BATH CHECK ALL LIGHTS 12) OUTLET NOT ALLOWED UNDER KITCHEN COUNTER OVERHANG 13) BANG PLATE CONDENSATE LINE 14) ADD H2.5 AT DIAGONAL DROP FRONT ROOM 15) MASTER EXHAUST DUCTS CRUSHED NOT SECURE 16) JACUZZI WILL NEED ACCESS TO MOTOR 17) GAS/POTABLE WATER/DWV OK