Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM05316

Parcel: 138133380

Inspection Status: Approved

Inspection History: SHEET ROCK NAILING

Date Description Inspector Results Comments
02/19/2004 SHEET ROCK NAILING Approved IVRS - Inspection 0000*
02/17/2004 SHEET ROCK NAILING Not ready for Inspection IVRS - Inspection 0000*
02/17/2004 SHEET ROCK NAILING Denied IVRS - Inspection 0999*/ 1) MASTER BEDROOM AND 2ND BEDROOM SHEAR WALLS DO NOT OUVERLAP BOTTOM PLATES BY A MINIMUM OF 3/4" 2) ONE STUD IN MASTER BATHROOM NOT NAILED 3) FILL ALL GAPS LARGER THAN 1/8" WITH HARD SETTING DRYWALL 4) REPLACE ALL DRY WALL SHEAR PANELS WITH TURN PAPER
02/12/2004 SHEET ROCK NAILING Not ready for Inspection IVRS - Inspection 0000*