Permit: T03CM05304

Parcel: 116273150

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T03CM05304

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
01/10/2004 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
01/06/2004 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) NOT COMPLETED
01/05/2004 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) PROVIDE FULL 10' HEAD PRESSURE 2) BACK WATER LEAKING 3) PROVIDE EXTENSION TO SURFACE FROM BACKWATER 4) 3/16' MAXIMUM SIZE ROCK IN TRENCH 5) SUPPORT ALL ON SOLID BED 6) 1/4" SLOPE REQUIRED THROUGHOUT 7) NOTE: RECOMMEND RELOCATION OF BACKWATER TO PREVENT SNAKE FROM DAMAGING CLAPPER WHEN USED. CLAPPER CAN BE REMOVED FOR SNAKING IF YOU PREFER THAT LOCATION