Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM05304
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/10/2004 | FRAMING | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
|
05/04/2004 | FRAMING | Partial Approval | IVRS - Inspection : See detailed listing on site.| 999*/ 1) BLOCK 3 SIDES AIR GRILLS 2) FIRESTOP ALL CHASES AT ENTERTAINMENT CENTER AND FIREPLACE 2) OK TO INSULATE ALLOW AREAS NOTED OPEN FOR INSPECTION |
|
05/03/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NO DWV WATER TEST 2) MASTER BATH WATER CLOSET REQUIRES 15" FROM F/F CENTER LINE TO FINISHED WALL 3) FIREPLACE REQUIRES FIRE STOP 4) ELECTRIC OUTLETS NOT ALLOWED UNDER KITCHEN COUNTER WITH OVERHANG OF 6" OR MORE 5) GAS AND ELECTRIC BONDS MUST BE ACCESSIBLE |
|
04/28/2004 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* |