Inspection Status: Denied
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/03/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* 1, 2, 3, 5, 9, NOT CORRECTED |
| 02/03/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/29/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) MAXIMUM ALLOWED LENGTH OF LAV TRAP ARM-42" 2) MAXIMUM ALLOWED SIZE OF LAV TRAP ARM 1 1/2" 3) LAV DIRTY ARM FLAT PITCHED 5) DOUBLE TOP PLATE OVER CUT AT A/C COPPER FHA STRAPS REQUIRE 6 EACH 16D EACH SIDE 6) NAIL PROTECT WIRES WITHIN 1 1/4" OF SURFACE BY FRIG CORNER 7) A/C CONDENSATE OUT OF WALL 8) SHEAR WALL BROKEN AT FRONT BEDROOM SEE 5/SD3 9) BEDROOM 2 SHEAR P-1 REQUIRES STUDS AT 16" ON CENTER |