Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/09/2004 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :*/ 1) COMPLETE WALL CANNOT BE HIGHER THAN 12' FROM FINISH FLOOR | |
| 06/02/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/ 1) PARTIAL UP TO 8' AND LINTEL HEIGHT | |
| 05/26/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/ 1) 1ST 48" LIFT OK TO GROUT 2) LAY BLOCK TO 8' HEIGHT, INSTALL REBAR 3) RECALL INSPECTION BEFORE GROUTING | |
| 04/30/2004 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) WINDOWS NOT INSTALLED SOUTH AND WEST WALLS 2) HORIZONTAL REBAR REQUIRED UNDER WINDOW OPENINGS 3) ROUGH OPENING BEGINS AT 2'-8" ABOVE FINISHED FLOOR ELEVATION |
|
| 04/12/2004 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection 0000*/ 1) LAY BLOCK TO 48" HEIGHT 2) INSTALL VERTICAL REBAR ( OVERLAPPING 30 BAR DIAMETERS) 20" MINIMUM ON #5 REBAR 3) INSTALL HORIZ REBAR WHERE INDICATED 4) CALL FOR 1ST LIFT 01020 (DO NOT GROUT) 5) MUST USE AGGREGATE IN GROUT |