Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 03/11/2004 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 03/10/2004 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ SAFTY GLAZING REQUIRED IN WINDOW AT NORTH SIDE DOOR. COMPLETE GRADING TO SLOPE AWAY FROM FOUNDATION. LABEL CIRCUITS SERVED IN MAIN ELEC. PANEL. CUT SEWER C.O. TO GRADE. INSTALL ANTI-SYPHON ON HOSE BIB. NEED INSULATION AND STUCCO CERT. INSTALL SANTEE AND BELL REDUCER FOR A/C CONDENSATE TO DUMP INTO VENT. INSTALL CAP ON MECH. VENT ROOF. INSTALL 40 AMP FUSES A/C DISCONNECT ON ROOF. PAINT EXPOSED ABS VENT PIPE ON ROOF. STOPPED INSP. NO ANSWER AT DOOR, NO ACCESS. |