Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/09/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 02/17/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) ITEMS NOT CORRECTED 2) REINSPECTION FEE DUE 3) SUBMIT AS BUILTS FOR APPROVAL 4) USE TECO NAILS INSTEAD OF SCREWS JOIST HANGERS 5) STOPPED INSPECTION 6) COMPLETE ALL TRADES AND RECALL 7) STRONGLY SUGGEST OBTAINING LICENSED CONTRACTORS TO COMPLETE JOB |
| 02/12/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 02/11/2004 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 02/09/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) COMPLETE GAS LINE INSTALLATION PER CODE 2) WRONG FITTING USED AT LAV WASTE, NEGATIVE FLOW AT VENT 3) PROTECT ALL WIRES AND PIPES CLOSER THAN 1 1/4" FROM FACE OF STUDS 4) FIRE BLOCK MISSING AT ALL FURDOWNS 5) USE APPROVED FAN BOXES |
| 02/02/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) 2 X 6 HEADERS FOR FIRE PLACE REQUIRE ULG HANGERS 6 EACH 2) CLOSET LIGHT MUST BE 12" IN FRONT FO SHELF 3) SHOWER REQUIRES 2" TRAP AND TRAP ARM 4) SHOWER VENT MUST EXTEND THRU ROOF 5) LAV PLUMBING TRAP ARM NOT IN 6) GAS LINES ARE NOT PER PLAN. BUILD TO PLAN OR HAVE PLAN REUSED AND SIZED TO AS BUILT 7) MINIMUM 10 PSI AIR PRESSURE TEST REQUIRED ON ALL GAS LINES 8) FIRE PLACE MUST HAVE AN INSIDE GAS SHUT OFF VALVE AND GAS LINE MUST BE COMPLETE TO INSIDE FIRE PLACE 9) MECHANICAL DUCT WORK NOT INSTALLED 10) HARD WIRED SMOKE DETECTORS REQUIRED IN BEDROOM AND FAMILY ROOM. ALL EXISTING BEDROOMS MUST HAVE BATTERY OPERATED SMOKE DETECTORS 11) FIRE BLOCK BEDROOM RAKE WALLS 12) JUNCTION BOX FOR OLD LIGHT CANNOT BE BURIED IN WALL |
| 01/02/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) REMOVE PAPER FROM EXTERIOR SHEATHING 2) INSTALL FIREPLACE 3) DRAFT STOP WALLS 25' MAXIMUM HORIZONTAL 4) INSTALL SMOKE DETECTOR 5) STOPPED INSPECTION COMPLETE ALL-FRAMING, PLUMBING, ELECTRIC AND MECHANICAL WHEN READY. |