Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/13/2004 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 01/12/2004 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) WATER CLOSET DOES NOT COMPLY WITH CURRENT CHAP 11 REQUIRED 18" FROM WALL. APPROVED AT 19 1/2" AS EXISTING INSTALLATION 2) ADDRESS # TO BE 12" PER PIMA COUNTY REQUIRES 3) GRAB BAR FOR RAMP GUARD SHOULD BE BETWEEN 34" AND 38" (IBC 1003.3.311.1) 4) IBC 1003.3.1.6 THRESHOLD APPROACH GREATER THATN 1/4" REQUIRED TO BE LEVELED AT 1:2 SLOPE 5) IBC 1003.3.7.8 INSTALL SIGN USING 1" LETTERS ABOVE ENTRANCE "THIS DOOR TO REMAIN UNLOCKED WHILE BUILDING IS OCCUPIED" 6) HARDWARE ON APA RESTROOM MUST UNLOCK AUTOMATICALLY WHEN HANDLE TURNED. IBC 1003.3.1.8 7) SIGNAGE TO RESTROOM MUST MEET CHAPTER 11 REQUIREMENTS (REF. ANSI 117-RAISED LETTERS AND BRAILLE CHARACTERS 8) PROVIDE PLUMBING FINAL-NEED REVISED PLAN TO CHANGE WATER HEATER FROM 30 TO 10 GALLON 9) SEAL TOP OF TILE AT WALL IN RESTROOMS |