Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/26/2004 |
SHEET ROCK NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 02/24/2004 |
SHEET ROCK NAILING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) GARAGE NOT READY |
| 02/23/2004 |
SHEET ROCK NAILING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) #4 SHEAR IN GARAGE NOT COMPLETE, ALL ELSE OK TO TAPE |
| 02/18/2004 |
SHEET ROCK NAILING |
|
Denied |
IVRS - Inspection 0999*/ 1) MAXIMUM ALLOWED GAPS BETWEEN DRYWALL PANELS 1/4" SOME GAPS 3/4" OR WIDER 2) SHEAR WALL 5 NOT NAILED BY A/C DUCTS 3) #4 SHEAR WALL REQUIRES 5/8" DRYWALL 4) #1 SHEAR WALLS MAXIMUM NAIL SPACING ALLOWED 7" EXCEEDED, RE-NAIL 5) CLOSET #5 SHEAR WALL NOT PER PLAN 6) EXCEPT PANTRY #5 |