IVRS - Inspection 0000*/ 1) ALL CORRECTIONS HAVE BEEN MADE. LEFT GAS CARD |
| 12/05/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 10 PSI TEST IS OK. / EXTEND T&P DRAIN LINE TO WITHIN 6" OF GROUND. DRAIN LINE CANNOT HAVE THREADS ON END OF PIPE. REPAIR DRAFT DIVERTOR AT TOP OF WTR HTR AND SECURE AS NEEDED. EXTEND VENT PIPE ON WTR HTR ABOVE EVAP COOLER WITH DBL WALL PIPE, NOT SINGLE WALL PIPE. USE "AMERIVENT" . RECALL FOR INSPECTION. |