Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM05220
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/23/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
12/19/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) STILL MISSING NAILING ON ROOF SEE RED MARKS 2) BRACE FLAT STUDS IN (FRONT TRUSS) AT VENT AND REAR PORCH 3) TRUSS STILL BROKEN 4) NAIL ALL HORIZONTAL JOINTS IN VERT. SHEAR 5) PLAN CALLS FOR A 6 X 12 PORCH BEAM 6) BROKEN FLAT STUD REAR GABLE, BRACE AT MID POINT | |
12/17/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) CHECK BEAM SIZE REAR PORCH 2) CHECK STAPLE SIZE 3) DRIVE ALL NAILS HOME IN CROSS BRACES AT TRUSSES 4) CHECK ROOF NAIL 5) NAIL OFF LATERAL BLOCKS (FREIZE) 6) NAIL OFF ALL SHEAR HORIZONTAL AND VERTICAL 7) HOLES IN SHEAR, NAIL OSB TO BLOCKS 8) CHECK FOR SHEAR, NAILERS (BLOCKS) IN GARAGE FOR DRYWALL 9) 3RD TRUSS FROM REAR WALL HAS A BROKEN VERTICAL MEMBER |