Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T03CM05214
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/13/2003 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000*/ WATER TEST ON WASTE AND VENT THRU ROOF OK. H2O PIPING WATER TEST OK, | |
11/10/2003 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000*/ 1) CONTRACTOR TO SUPPLY 3" UTR. 2) CONTRACTOR TO SUPPLY 3/4 HOT WATER DOWN TO FIXTURES AND 1/2" HOT TO SERV. SINK. ROUGH SOIL WATER TEST ONLY OK. | |
11/07/2003 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000*/ 1) PLUMBING PLAN APPROVED IN ERROR, BACK TO BACK STOOLS REQUIRE 2 PIPIE SIZES LARGER ON VERTICAL WASTE THAN STOOL ARMS. 2) ADDITION OF SINK IN NORTH EAST CORNER OF RESTROOM NEEDS TO BE ADDED TO CITY APPROVED PLANS. | |
11/06/2003 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000*/ 1) PLEASE INSTALL PER PLAN OR HAVE APPROVED CITY STAMPED PLAN ON SITE SHOWING CHANGES. 2) WATER OR AIR TEST THRU ROOF. |