Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T03CM05181
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/06/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 04/06/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 100 PSI AIR TEST ON 2 LOADING DOCK SUMP PUMPED 1¼" PVC SCH 40 DRAINS OK. | |
| 04/02/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1¼ SUMP PUMP PIPING, PVC SCH 40 USING 45o FITTINGS FROM BOTH LOADING DOCKS SUMPS TO WEST LOADING DOCK EXTERIOR WALL. 1) WILL REQUIRE AIR TEST AND LETTER FROM ENGINEER STATING MATERIEL TYPE IS OK. | |
| 03/24/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1) 6" SEWER CHANGE OUT FROM CLAY TO CAST IRON NO HUB UNDER LOADING DOCK WATER TEST OK 2) PLEASE PROVIDE CLEANOUTS ON THIS MAIN SITE SEWER EVERY 100' MAX TO ACCOMADATE PROPER CLEANOUT OF DRAINAGE | |
| 03/16/2004 | PLUMBING - INTERMEDIATE | Partial Approval | ||
| 02/13/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ [12] 4" OVERFLOW RAIN DRAINS FOR SPORTS MART WTR TEST STUBBED OUT OF SOUTH SIDE OF BLD. 0K PENDING ENGINEER STAMP FOR NOTED LOCATION OF TERMINATION. | |
| 12/30/2003 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ WATER TEST ON EXISTING 4" RAIN DRAIN TOTAL [30] ON BLDG. THIS INSPECTION FOR DRAIN # 10 - 20 FROM EAST TO WEST CENTERLINE 5 - CENTERLINE 10 APP. ROOF HAS EXISTING RAIN DRAIN BODIES INSTALLED POSIBLE FOR OVERFLOW DRAINS THAT ARE COVERED OVER AND NOT PIPED. ROOF HAS EXISTING CRICKET ON SOUTH END FORCING WATER ON ROOF TO EXISTING DRAINS. ARCH OR ENGINEER TO VERIFY ROOF DRAINAGE THAT IS EXISTING WILL HANDLE RAINFALL. IF NOT PLEASE PROVIDE CITY APPROVED DRAWING SHOWING ADDITIONAL DRAINS OR OVERFLOW DRAINS IF REQUIRED. |