Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM05156
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/11/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
02/09/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) NAIL END TRUSS TO DOUBLE TOP PLATE ABOVE ELECTRIC SERVICE 2) TIE LARGE FRONT WINDOW POP OUT TO MAIN FRAME 3) SPF STUDS USED EAST WALL NOT PER PLAN 4) TIE FRONT WALL TO ROOF, LAST TIME ENGINEER SAID DON'T USE AGAIN 5) BRING ALL PT. LOADING DOWN FROM 2ND FLOOR TO 1ST FLOOR 6) SHIM ALL 3 PT BEARING TRUSSES IN GARAGE 7) NAIL HORIZONTAL JOINTS REAR WALL 8) NEED WIND BRACE FRONT WALL 9) X BRACES FOR TRUSSES, USE NAILS IN SHEAR, NOT TOE NAILS 10) FRONT CRICKET TO FLAT 11) NAIL STUDS TO WALL FRONT POP OUT 12) SEE ALL BLACK MARKS ON ROOF 13) WATER HEATER FLUE NOT RIGHT |