02/11/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
02/09/2004 EXT METAL CLIPS/EXT SHEATHING Denied 1) NAIL END TRUSS TO DOUBLE TOP PLATE ABOVE ELECTRIC SERVICE 2) TIE LARGE FRONT WINDOW POP OUT TO MAIN FRAME 3) SPF STUDS USED EAST WALL NOT PER PLAN 4) TIE FRONT WALL TO ROOF, LAST TIME ENGINEER SAID DON'T USE AGAIN 5) BRING ALL PT. LOADING DOWN FROM 2ND FLOOR TO 1ST FLOOR 6) SHIM ALL 3 PT BEARING TRUSSES IN GARAGE 7) NAIL HORIZONTAL JOINTS REAR WALL 8) NEED WIND BRACE FRONT WALL 9) X BRACES FOR TRUSSES, USE NAILS IN SHEAR, NOT TOE NAILS 10) FRONT CRICKET TO FLAT 11) NAIL STUDS TO WALL FRONT POP OUT 12) SEE ALL BLACK MARKS ON ROOF 13) WATER HEATER FLUE NOT RIGHT