Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 04/09/2004 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*/ CLOSET FLANGE OK. OK TO COVER ALL AREAS. |
| 03/03/2004 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) PVC THRU ROOF OK. COPPER OK. 2) NEED TO SEE CLOSET FLANGES. 3) NOTE - CONDENSATE DRAIN SIZE MAY NOT BE REDUCED AT LAVATORY CONNECTION. 4) OK TO COVER ALL AREAS. |
| 02/25/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 02/18/2004 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/ THREE SETS OF ROOF DRAINS AND OVERFLOWS UNDER SLAB OK. PIPE WRAPPED AND OK TO POUR CONCRETE. |
| 01/05/2004 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/ CORRECTIONS MADE OK. OK TO COVER UNDERGROUND. |
| 12/30/2003 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ NOBODY ON SITE. UNABLE TO LOCATE PLAN OR PERMIT. |
| 12/22/2003 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) FARNCO NON-SHIELDED COUPLINGS NOT APPROVED FOR UNDER THE BLDG |