Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/17/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 07/01/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NEED PLAN/PERMIT ON SITE IN OBVIOUS LOCATION 2) NEED GAS PRESSURE TEST 3) BANG PLATE WIRES WHERE CLOSER THAN 1 1/4" FROM FACE OF STUDS AND RAFTERS 4) NEED SHEETROCK NAILERS IN SEVERAL AREAS |
|
| 06/09/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/' 1) OK TO INSULATE AND ROCK WALLS 2) NEED LIGHTS AND DUCTS | |
| 05/19/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SECURE AB'S-90 DEGREE 2) BANG PLATE ELECTRIC AND PLUMBING WHERE NEEDED 3) MOVE DINING EAST WALL OUTLET 4) FINISH FRAME AND CHANGE HEADER 5) CORRECT PATIO DOOR HEADER 6) ADDRESS 2 X 6 RAFTERS 7) MOVE PEX FROM CANS 12" |
|
| 05/13/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :*/ 1) WITH A 2 X 4 EXTERIOR WALL THE MESH MUST BE COMPLETE BEFORE INTERMEDIATE INSPECTIONS WILL BE PERFORMED |