Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/02/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/29/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) FIREBLOCK CHASES AT GARAGE 2) MISSING RIDGE BOARD IN 2ND BAY 3) REPAIR PAPER AT CONDENSATE PROTRUSION 4) CORRECT TC CLIP NAILING 5) FIREBLOCK AT KITCHEN SOFFIT 6) BANG PLATE BACK OF DRYER VENT AND TPR LINE IN BED 7) SHIM HEADERS |