Permit: T03CM05079

Parcel: 137070500

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T03CM05079

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
11/02/2004 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*/ 1) ALL CORRECTIONS HAVE BEEN MADE
10/28/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) DOOR WAS LOCKED
10/28/2004 PLUMBING - INTERMEDIATE Denied SHALL USE A SPECIALTY COUPLINGS NOT A NO HUB COUPLING FOR CONNECTIONS ABS TO ABS
10/22/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)CAN NOT USE A RUBBER TEE FOR DRAINAGE FITTING. THIS FITTING SHALL BE SOLID WELD OR BRASS SLIP JOINT FITTING. IF YOU USE A SLIP JOINT FITTING THEN YOU ARE REQUIRED TO PROVIDE AN ACCESS PANEL
06/01/2004 PLUMBING - INTERMEDIATE Partial Approval 1) WASTE AND VENT SYSTEM IS CAST IRON AND IS IN GOOD CONDITION. 2) MUST SEE INSTALLATION OF TUB WASTE AND OVERFLOW. 3) OK TO DRYWALL UPON BLDG INSPECTORS APPROVAL.