Permit: T03CM05070

Parcel: 126132700


Addresses:

4656 E 16TH ST

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
12/02/2003 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection 0000*
11/25/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000* 1) LAY YOUR BLOCK UP TO FULL HEIGHT AND RECALL. I NEED TO SEE HOLD DOWNS IN PLACE @ TOP BEFORE YOU GROUT. 2) OK TO GROUT 4'
11/24/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000* OK TO GROUT 24" ONLY. VERTICAL LAP SPLICE ABOVE 4' LEVEL OF BLOCK HAS NOT BEEN MAINTAINED.