Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM05038

Parcel: 141175670

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T03CM05038

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/11/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
12/10/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) SEE LAST INSPECTION 2) BRACING NOT MORE THAN 60 DEGREE OR LESS THAN 45 2) NAILS TO BE IN SHEAR, NOT TOE NAILED
12/08/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) NAIL OFF OSB 2) NAIL CORNERS TOGETHER 3) REMOVE NAILS FROM WEEP SCREED SO BOTTOM PLATE AND MAS HD'S CAN BE SEEN 4) MISSING CROSS BRACE AT FRONT OF GABLE
12/04/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) OK TO LATH 2) ADD X BRACE TO TRUSSES FRONT 3) SHEAR PANELS NOT MADE OR NAILED CORRECTLY 4) FIX HOLE REPAIR 2 IN GARAGE 2 INSIDE HOUSE
12/02/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) REMOVE FOAM AT SHEAR WALLS 2) SHEAR PANELS NOT MADE OR NAILED CORRECTLY 3) ROOF MARKED FOR MISSED NAILING 4) WRONG NAILS IN HANGERS AT GARAGE 5) ADD X BRACING AT FRONT OF GABLE 6) ANGLE FOR BRACES NOT MORE THAN 60 DEGREE OR LESS THAN 45 DEGREE 7) CHECK ALL HOLE REPAIRS AT SHEAR NAIL OSB TO BLOCKS