Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM05038
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/11/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
12/10/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) SEE LAST INSPECTION 2) BRACING NOT MORE THAN 60 DEGREE OR LESS THAN 45 2) NAILS TO BE IN SHEAR, NOT TOE NAILED | |
12/08/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) NAIL OFF OSB 2) NAIL CORNERS TOGETHER 3) REMOVE NAILS FROM WEEP SCREED SO BOTTOM PLATE AND MAS HD'S CAN BE SEEN 4) MISSING CROSS BRACE AT FRONT OF GABLE | |
12/04/2003 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*/ 1) OK TO LATH 2) ADD X BRACE TO TRUSSES FRONT 3) SHEAR PANELS NOT MADE OR NAILED CORRECTLY 4) FIX HOLE REPAIR 2 IN GARAGE 2 INSIDE HOUSE | |
12/02/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) REMOVE FOAM AT SHEAR WALLS 2) SHEAR PANELS NOT MADE OR NAILED CORRECTLY 3) ROOF MARKED FOR MISSED NAILING 4) WRONG NAILS IN HANGERS AT GARAGE 5) ADD X BRACING AT FRONT OF GABLE 6) ANGLE FOR BRACES NOT MORE THAN 60 DEGREE OR LESS THAN 45 DEGREE 7) CHECK ALL HOLE REPAIRS AT SHEAR NAIL OSB TO BLOCKS |