Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T03CM05033
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/25/2004 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
10/21/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
10/19/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/ 1) 24' AT INFILL | |
10/18/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
10/15/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :16" @ FILL | |
10/13/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/1)WINDOW WALL PER RED LINE CHANGE (SOLID GRANT?) 2)8' @ INFILL | |
10/07/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* TOP OUT @ COLUMNS ALL THATS LEFT IS IN FILL | |
09/30/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/28/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/TAPPED OUT EXCEPT CDS?, INFILL, EAST RAKE | |
09/24/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/TOP OUT WEST RAKE? | |
09/21/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*PARTIAL APPROVAL. 32' A/2-3; 28' G/2-3 | |
09/17/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/ 1) 1ST LIFT AT 4' SCREEN WALL | |
09/15/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/ 1) 18' LINE E; 18' LINE G/2.2-3; 18-22' RADIUS LINE 3 E-H, TOP LINE 2.2/ZZ-A; 28' LINE A/2-3 | |
09/10/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | PARTIAL | |
09/08/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/TAP OUT LINE A & G - 12 @ RADIS F-H TAG? G-4/2-3 | |
09/02/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :TO WELD PLATES LINE A 2.5/3; TOP ZZ-A/1.5-2 8' AND 12' LIFTS AREA G-H | |
08/31/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/ 1) TO LEDGER WELD PLATES LINE A AND G 2) 8' AREA G-H RADIUS WALL 3) PROGRESS OK AREA ZZ-A | |
08/27/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :CONTINUED PROGRESS ON RADIUS WALLS A & G OK PROGRESS INAREA G-H/2-3 OK VARIOUS HEIGHTS 4'-12' PROGRESS @ ZZ-A (LINE A 2-3) OK |
|
08/26/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :TOP LINE 2/A-C; 20' ZZ-A/2-3; 3?' LINE A&B | |
08/25/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/24/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/P-1) 20'8" 22-A 2) TOP D-6 LINE 2 3) 4' & 8' VARIOUS EVRESS G-H 4) 32' LINE A & LINE G | |
08/20/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 32' LINE A, 32' LINE G, 30' LINE ? | |
08/18/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/ 1) 16'/ZZ-A | |
08/16/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/13/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :12' 22-A/28' LINE A | |
08/12/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/10/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/05/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/02/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
07/29/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/ 1) 20' LINE 1/A-G; 20' LINE A/1-2 | |
07/27/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
07/26/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :1ST LIFT | |
07/22/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :16' A/1-2 18' 2/A-G | |
07/19/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*GRID 1 A THRU G. GRID G #1 THRU 2. GRID E #3. CLEAN BOTTOM OF FTGS. AND ALSO REBAR. | |
07/15/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*LINE 1 AND LINE A-1-2 AT 12'. | |
07/13/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*SEE YESTERDAY'S NOTES. | |
07/12/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*12' LINE G/1-2 AND LINE 1/A-F(?). | |
07/08/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
07/06/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* OK TO 8' G/1-2, A/A-G, A/1-2, 2/A-G. | |
06/30/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
06/28/2004 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*/ 1) LINE G/1-2 AND LING G-1-2 AND LIVE 2/G-F AT 4' AFI |