Permit: T03CM05002

Parcel: 140373800


Addresses:

7067 S PLOVER CT

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/05/2004 FRAMING Approved IVRS - Inspection 0000*
12/30/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) VENT INSTALL NOT PER PLAN 2) NO TEST ON DWV'S AND COMPLY WITH TABLE 10.1 UPC HORIZONTAL DISTANCES OF TRAP ARMS 3) TRUSS C 1A BOWED 4) PROVIDE APPROVED FRAMING DETAIL FOR LIVING AND FRONT PORCH AREA 5) NEXT FAILURE WILL RESULT IN A DOUBLE REFEE
12/23/2003 FRAMING Denied IVRS - Inspection 0999*/ REPLACE STUD AT GARAGE WALL. ANCHOR BOLTS MISSING NUTS. SHEATHING NOT NAILED IN GARAGE.
12/19/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) NOTHING DONE FROM LAST INSPECTION. HAVE SUPERVISOR WALK HOUSE AND RECALL WHEN READY IN EXT FAILURE WILL RESULT IN A REFEE
12/17/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) PROVIDE TRUSS CALCS 2) CIA TRUSS BOWED 3) COMPLY WITH DETAIL 14SD4 NAILING 4) ROMEX NOT ALLOWED TO BE STAPLED ON IT'S SIDE. TABLE E3702.1 5) NO TEST ON DWV'S OR WATER LINES 6) 2" TRAP ARM NOT ALLOWED AT LAV'S 7) LATH NOT COMPLETE 8) TOO MANY ITEMS. HAVE TRADES CHECK AND RECALL WHEN READY