Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/16/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 03/08/2004 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000* |
| 03/05/2004 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) NO TEST ON DWV'S 2) PLUMBING OUT OF WALL AT LAUNDRY ROOM 3) WATER LINES MUST BE 12" AWAY FROM CAN LIGHTS 4) TEST AT 7 PSI, 10 PSI REQUIRED 5) SUPPORT AB'S THROUGHOUT 6) ATTIC ACCESS NOT ACCESSIBLE |
| 03/04/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PLUMBING OUT OF WALL AT LAUNDRY 2) WIRE IN CONTACT WITH W/H FLUE 3) PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AT FLUES 4) ATTIC ACCESS RESTRICTED 5) SECURE DWV'S |
| 03/04/2004 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) CANCELLED ON SITE |
| 03/01/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0935*/ 1) GAS TEST AT 0 PSI 2) NO TEST ON DWV'S 3) REVISE PLUMBING PLAN TO SHOW CHICAGO LOOP 4) PLASTIC WATER LINES MUST BE 12" AWAY FROM CAN LIGHTS 5) NOTHING DONE FROM LAST INSPECTIONS 6) REFEE |
| 02/27/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) MISSING ONE EAVE VENT 2) COMPLY WITH WCPC INSTRUCTIONS 3) FRONT ENTRY EAST NOT LATHED 4) GROUND EXTERIOR METAL BOX SOUTH WEST CORNER 5) NO TEST ON DWV'S 6) NO TEST ON GAS LINE 7) SEE LAST INSPECTION 8) STOPPED INSP. HAVE TRADES WALK HOUSE AND RECALL WHEN READY, NEXT FAILURE WILL RESULT IN A REFEE |
| 02/26/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE AN APPROVED DETAIL FOR CHICAGO LOOP AT KITCHEN ISLAND APPROVED BY CITY OF TUCSON 2) NO TEST ON DWV'S 3) GAS PRESSURE TEST AT ZERO 4) WATER LINES MUST BE 12" AWAY FROM CAN LIGHTS 5) STOPPED INSPECTION, HAVE TRADES AND SUPERVISOR WALK HOUSE BEFORE RECALL |