Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/10/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 03/08/2004 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) SEE LAST INSP 2) NEED ENGINEERING STAM BY ENGINEER AND CITY OF TUCSON |
| 03/04/2004 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NO WATER IN DWV OR POTABLE WATER 2) FHA STRAP AT DRYER DUCT 3) LAUNDRY, ADD STUD UNDER BEAM 4) BLOCK ALL MECH DUCTS 5) EAST BEDROOM, MISSING SMALL PLATE 6) RAT RUNS ON B-TYPE TRUSSES 7) NO WATER IN WEST SHOWER PAN, SAME AREA, DIVERTER STUD OVER SPAN 8) NEED SHEAR (INTERIOR) TRANSFER DETAILS AND MECHANICAL REVISIONS 9) LOOSE STUD, BANG PLATE KITCHEN 45 DEGREE WALL 10) NEED GIRDER TRIPLE 2 X CONENCTION ON PLAN HANGER SIZE |
| 03/03/2004 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) CANCELLED BY SUPER |