Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/08/2004 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 01/07/2004 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1) NAIL OFF DOUBLE TRUSS AT SOUTH ROOF PLANE FRONT 2) STRAP TOP PLATES SOUTH OF PATIO 3) STRAP TRUSS DOWN-GABLE SOUTH OF PATIO |