Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM04984

Parcel: 131070650

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T03CM04984

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
08/11/2005 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
1) APPROVED PLAN ON SITE
11/29/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/60 PSI AIR TEST ON H2O SYSTEM OK. 1)ALL HOSE BIBS WILL REQUIRE SIGNAGE THAT THEY ARE NON POTABLE. DO NOT DRINK DOWN STREAM OF BFP-2. WATER TEST ROOF DRAINS (3) SESTS 3" RAIN DRAIN & OVERFLOW RAIN DRAINS OK. WASTE &VENT WATER TEST THRU ROOF PER RED LINE DRAWING INITIALED BY P.E. #19282 AZ. HAVE THIS ADDED TO YOUR REVISED CITY APPROVED DRAWINGS
09/24/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*/03055-4" BUILDING SEWER SDR35 FROM STUB AT PLANT ENCLOURE RUNS SOUTH 25' THEN WEST T BLD 2. BUILDING SEWER 5' SOUTH OF 2-WAY CLEANOUT AT BLD 2 WATER TEST OK PENDING CITY APPROVED REVIDED PLAN OF RED LINE DRAWING ON SITE