Permit: T03CM04982

Parcel: 131070650

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T03CM04982

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/18/2005 PLUMBING - FINAL Approved IVRS - Inspection :* TURNED IN (10) BACKFLOW CERTIFICATIONS
TURNED IN (1) BOILER REPORT.
BUILDING INSPECTOR TO RECEIVE BACKFLOW CERTIFICATION FOR TEA BREWER IN CAFE.
10/14/2005 PLUMBING - FINAL Partial Approval IVRS - Inspection :NEED (1) BACKFLOW CERTIFICATION FOR DEVICE AT CAFE FOR TEA BREWER ONLY AND ALL OTHER BACKFLOW CERTIFICATION WITH STATE BOILER APPROVAL TO COMPLETE JOB*
09/09/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) SEE NOTES FROM PAST INSPECTIONS
08/26/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) BOILER VENTING OK
2) GAS CARD AT METER
3) PROVIDE STATE BOILER INSPECTION AND ITEMS FROM PAST INSPECTIONS
08/11/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
08/10/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
07/29/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) NEED TO SEE HEARTH ? PLAN OF IKE'S CAFE
2) 2-COMP SINK SHOWN GOING DIRECT WASTE-3COMP INSTALLED GOING INDIRECT. PLEASE SEE NOTES FROM 7/11/05 AND 7/15/05 AND COMPLY. NEED REVISION FOR JANITOR ROOM 125 REVISED PLAN SHOWS MOP SINK, FLOOR SINK, AND FLOOR DRAIN ONLY MOP SINK AND FLOOR SINK INSTALLED. NEED INSTALL OF EYE WASH SHOWER IN CENTRAL PALN ENCLOSURE. NEED PROOF OF STATE BOILER INSPECTION
07/28/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
SEE NOTES FROM 7/11/05 INSPECTION
ALL INDIRECT DRAINS TO BE FULL SIZE RIGID PIPING OVER 5" TRAPPED OVER 15' P-TRAPPED & VENTED WITH CLEANOUTS IF REQUIRED. PREVIOUS SIGNAGE FOR HOSE BIB AT EFFECTS FOUNTAIN FILTER EQUIPMENT PER 94 UPC SECTION 603.3.11 DANGER UNSAFE WATER AND VACUUM BREAKER
07/15/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* COMPLETE ALL PLUMBING WORK THEN CALL INSPECTIONS.
07/11/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 1) CALL IN ALL INSPECTIONS THAT HAVE NOT BEEN APPROVED AND HAVE RED LINES & REVISED CITY APPROVED PLANS ON SITE. 2) PROVIDE ACCESS TO COOLERS TO VIEW H20 AIR GAP. 3) INSTALL HOSE BIBS WITH VACUUM BREAKERS. 4) SEAL ALL PIPE PENETRATIONS INTO BUILDING. 5) PROVIDE CERTIFICATIONS FOR ALL BACKFLOW DEVICES. 6) ALL FLOOR CLEANOUTS TO BE FLUSH TO FINISH FLOOR. 7) VENTS THRU ROOF REQUIRE FLASHING AND SHALL BE MINIMUM 1' FROM BUILDING SIDE WALL 8) ICE MACHINES REQUIRE PROOF OF 1" AIR GAP FOR H2O SUPPLY OR CORRECT BACKFLOW PROTECTION, AND SEPARATE INDIRECT DRAINS. 9) EXPOSE ALL CLEANOUTS AT SINKS &PROVIDE CLEANOUT COVERS. 10) CHECK YOUR WATER HEATER PIPING DETAIL & SUPPORT EXPANSIOPN TANK. 11) COFFE MAKERS WILL REQUIRE SEPARATE BACKFLOW PROTECTION. 12) STOLL REQURE MINIMUM 15" SIDE WALL OBSTRUCTION CLEARANCE. HAVE ALL FIXTURES FUNCTIONAL . THIS IS NOT A COMPLETE LIST