Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T03CM04982
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/29/2005 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
04/14/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 3/4 COPPER PIPING TIES INTO 3" BUILDING SERVICES AT BUILDING ENTRANCE UNDERGROUND UP TO BACKFLOW DEVICE UNDERGROUND TO FUTURE FOUNTAIN IN COURT YARD OK PENDING ADDITION TO PLAN. | |
02/16/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*2" VENT CHANGED TO 3" WATER TEST THRU ROOF OK 4" VENT COMBINATION WASTE & VENT SOUTH WEST CORNER WATER TEST THRU ROOF.OK | |
02/14/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 4" VENT WATER TEST THRU ROOF NORTH EAST AREA DRAIN IN SERVICE BAYS OK. WASTE & VENT IN WALL WATER TEST LUNCH 156, WOMEN 160, TECH RR 161, JANITOR 163 OK 1) NEED TO HAVE 3" VENT IN CEILING FOR OVER 40" HORIZONTAL ON 2" VENTING. H20 PIPING LUNCH 156, WOMEN 160, TECH R.R. 161, JANITOR 163 80 PSI AIR TEST OK IN WALL & OVERHEAD. H20 PIPING IN SERVICE BAYS 80 PSI OVERHEAD OK UP TO 1" STUB FOR H20 BACKFLOW DEVICE 1) NEED TO VIEW RP INSTALLATION AND PIPING CONTINUATION AND TERMINATION TO COOLERS. | |
01/26/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* PARTIAL APPROVAL. ADDITION OF FILTER PIPING IN STORAGE # 115 THAT IS CHANGED TO IKE'S CAFE IS OK. PENDING REVISED CITY APPROVED DRAWINGS OF RED LINES ON SITE. MANY FIXTURES HAVE BEEN ADDED AND ?? CHANGES ARE IN PROGRESS. PLEASE PROVIDE CITY APPROVED REVISED PLANS AS SOON AS POSSIBLE TO KEEP JOB PROGRESS GOING | |
01/19/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WASTE & VENT WATER TEST STORAGE # 115, WOMEN AND MES 123 & 124, WOMEN & MENS 134 & 135 & SINK INLUCH 148. H20 PIPING IN WALL & OVERHEAD IN THIS AREA 60 PSI TEST OK. REST ROOM 128 & JANNITOR 125 WASTE & VENT WATER TEST & H20 TEST OK ALL THRU ROOF ON WASTE & VENT. 1) OVERHEAD VENT PIPING TO BE SUPPORTED AT CORRECT INTERVALS 2) REVISED CITY APPROVED PLANS ARE NEEDED. 1 1/2 PVC SCH 40 DWV ELEVATOR SUMP PUMP PIPING 5PSI TEST OK PROVIDING LETTER FORM ENGINEER OK FOR PVC ??? TO BE USED. |