Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T03CM04982
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/19/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :*ALL SPECIAL INSPECTION REPORTS REVIEWED AND OK. OK C OF O | |
09/09/2005 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* PROVIDE FINAL INSPECTION REPORTS FROM ALL TRADE AND C OF O INSPECTORS |
|
08/25/2005 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* PROVIDE ITEMS LISTED BELOW (8.11.05) |
|
08/11/2005 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) STRUCTURAL AND EGRESS COMPLETE 2) I NEED PLUMBING AND C OF O INSPECTIONS FINALED 3) MY CONCERN IS WITH GETTING CAFE PLANS DONE AND GETTING BOILER COMPLETED 4) ELEVATOR MUST BE COMPLETE |
|
07/26/2005 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE FINAL INSPECTION REPORTS FROM PLUMBING, ELECTRIC, MECHANICAL AND ALL C OF O INSPECTORS 2) IBC SECTION (2000 IBC) 1003.1.8 ONLY THE MAIN DOOR OR DOORS MAY USE THE EXCEPTION TO LOCKS AND LATCHES BEING READILY OPENABLE FROM EGRESS SIDE 3) IN ADDITION TO ABOVE ANY ACCESSIBLE EGRESS REQUIRES THAT LATCHES AND LOCKS REQUIRE NO TIGHT PINCHING, TWISTING OR GRASPING |