Permit: T03CM04982

Parcel: 131070650

Inspection Status: Approved

Inspection History: BUILDING PRE-SLAB

Permit Number - T03CM04982

Inspection Description - BUILDING PRE-SLAB

Inspection Status - Approved

Date Description Inspector Results Comments
04/12/2005 BUILDING PRE-SLAB Approved IVRS - Inspection :*
01/21/2005 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*OK TO PLACE RAMP SLAB WHEN SPECIAL INSPECTOR CONFIRMS REPAIR FOR LOST DOWELS
12/27/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
1) MEZZANINES OK
12/20/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
1) MEZZANINE'S OK TO POUR
12/09/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
1) DECK 1-7/A-J OK TO PLACE
12/07/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
1) ? STEEL OK EXCEPT 1 MECH PAD, 2 SLAB DOWELS AT RAMP NEED TO HAVE RUBATEX AND HOOK MUST BE BEHIND CENTER LINE OF BEAM (21/37.3)
2) FINAL CLEARANCES NEAR SLAB EDGES
3) ? PROFILES OK WITH MINOR ADJUSTMENTS
4) ? COUNT NOT YET DONE
5) REPAIR TEARS AND VOIDS IN SHEATHING MAX 1" EXPOSED AT LIVE END, 12" DEAD END
12/06/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
11/17/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
09/24/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*/DECK POUR "A" READY TO PROCEED
09/23/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
09/22/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*/ 1) HIGH AND LOW POINTS ARE CRITICAL 2) RE-LOCATE WHERE NOT CHAIRED PER PLAN
09/21/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*PARTIAL APPROVAL. STAPLE ALL CHAINS SUPPORTING CABLES. MAINTAIN CGS @ CENTER OF SLAB @ ?-11. BOLSTER ALL BOTTOM BARS AS NECESSARY. CAP HEAD STEEL MUST BE SUPPORTED IN T.O.S. PLANE.
09/16/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*/ 1) MET WITH JEFF RYER (ENGINEER) AND WENT OVER ACCESSARY REPAIRS AND HOW TO ADDRESS MY CONFLICTS 2) MECHANICAL ROOM COMPLETE
09/15/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*/ 1) CHAIRS ? STEEL AT DRAG BARS AND DRAPES AT BEAMS
09/14/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
09/13/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*/STAPLE CHAIRS? STRAIGHTEN CABLES, WATCH CLEARANCES @ PENETRATIONS
09/10/2004 BUILDING PRE-SLAB Partial Approval PARTIAL CABLES UST MAKE SMOOTH CURVES. MOVE MILD REIFORCEMENT TO ALLOW FOT THAT
09/09/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*/PROG HEADS OK, CAPITAL HEADS @ COLS? OK
4'@ MECH ROOM
09/08/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*/PROGRESS OK
DO NOT GREASE CAP FORMERS?
RECHECK UNIFORM TENDER? ELEVATIONS @ ENDS OF BEAMS. THEY MAY GO OVER BANDEDS? RATHER THAN THE TYPICAL UNDER @ COLUMNS
09/07/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
09/02/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :REVIEW
09/01/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :I NEED ANSWER ON STAGGER BARS
TOP OUT @ NW STAIR
08/31/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*/ 1) GENERAL REVIEW
08/30/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*/PARTIAL-GENERAL SERVICE
08/27/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
08/26/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
08/25/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
08/24/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*/P-REVIEW-DROP HEADS REPLACED & NOW MATCH PLAN
LINE A/1-2 8' 8' LINE2/EF 21'4"
08/20/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :* PLEASE REPLACE 2 KINKED CABLES
08/19/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :* REVIEW- PLEASE CUT PLASTIC WHEN CABLE KINKED FOR INSP.
08/18/2004 BUILDING PRE-SLAB Partial Approval 1) GENERAL REVIEW AND CONSULTATION
08/17/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*/PARTIAL-REVIEW & CONSULTATION
1020-16'8" STAIR AREA
08/16/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*/P-REVIEW DECK LAYOUT
08/13/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :PLEASE PROVIDE RFI
RE: DETAIL 4 PPS70L
LOWER DROP CAP BARS FRABRICATED WITH 3 1/2-4" HOOKS INSTEAD OF 6" IN TYPICAL DETAILS
08/12/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
08/12/2004 BUILDING PRE-SLAB Not ready for Inspection IVRS - Inspection :*/ 1) PERMANENTLY RELEASED WALLS AND COLUMNS MUST TERMINATE AT OR SLIGHTLY BELOW P.T. SLAB. DO NOT LET THEM KEY UP INTO DECK 2) REBAR SHOP DRAWINGS MISSING #8 STEEL FOR 7' EXTENSION PER KEYNOTE 19 ON PPS3.2. ROD BUSTERS AND HARD ROCK NOTIFIED
08/10/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*/PARTIAL-GENERAL REVIEW
08/09/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*/ 1) PRELIMINARY DECK INSPECTION: CHECK COLUMNS AND WALL PENETRATIONS INTO DECK. REF DETAIL 8 PP S7.3 FOR EDS. PERMANENTLY RELEASED WALLS AND COLUMNS MAY NOT PENETRATE INTO SLAB AT ALL
07/28/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*PARTIAL SOG COMPLETE
07/14/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :* 4-7
06/30/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*
06/23/2004 BUILDING PRE-SLAB Partial Approval 1) 2ND POUR
06/17/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*/ 11-14/A-J PLEASE FINISH REMOVING LOOSE SAND AT FOOTINGS.
06/16/2004 BUILDING PRE-SLAB Partial Approval IVRS - Inspection :*/ 1) RECALL FOR TOMORROW