Inspection History Details
Inspection Status: Approved
Inspection History: STEM WALL/RETAINING WALL
Permit Number - T03CM04982
Inspection Description - STEM WALL/RETAINING WALL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/12/2005 | STEM WALL/RETAINING WALL | Approved | IVRS - Inspection :* | |
01/13/2005 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1025 EXTERIOR SHEATING HIGH SOFFITS OK SHEATING OK CDS OK SOUTH SIDE LOW WALLS UNDER DRIVE PARTIAL | |
07/08/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
06/08/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) COLS G10 & H10 OK TO CLOSE AFTER SPEC INSP ON WELD PLATES & WELDABLE REBAR PER SK2. 2) F9 & F10 OK TO CLOSE | |
06/04/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* COLS IN MEZZ AREA 10' 6"-20' OK AS NOTED | |
06/03/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) TOP OF COLS LINE8/B, C, D, E. 2) TOP OF COLS LINE 9, D. 3) COLUMN @ ELEVATOR SHAFT OK | |
06/02/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
06/01/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :*COLS LINE J/11-14 LINE K/11-14 | |
05/27/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :*/ 1) COLS LINE J CC5 COLS AT 11,12, 13, 14 OK 2) CC7 COL AT 10/E OK | |
05/26/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
05/25/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :*/ 1) LINE 8 TO 10'-6" B-H 2) LINE 9 TO 10'-6" E-H 3) LINE 10/E-H MATCH VBERTS TO DOWELS FOR PROPER CLEARANCE 4) LINE 12-B,C,D AND E OK 5) LINE 13-CDEF OK 6) LINE 14-BCDE ADD SPACERS/CHAIRS OK TO CLOSE | |
05/24/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :*/ 1) LINE 8 TO 10'-6" COLS. OK TO CLOSE AND POUR | |
05/21/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :*/ 1) COLUMNS LINE 11 OK 2) 3 COLUMNS LINE 13 OK TO CLOSE WHEN SPEC. INSPECTOR CONFIRMS FINAL TIES | |
05/20/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :*/ 1) COLUMNS LINE 5, LINE 6-OK | |
05/18/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :*/ 1) LINE 5 COLS. A) TIE ADJACENT DOWEL/COL VERTS TOGETHER B) RING TIES TO BE HORIZONTAL-PLEASE CLEAN UP DISTURBED TIES | |
05/17/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :*/ 1) LINE 2/BCD 2) LINE 3/ALL | |
05/13/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :*/ 1) LINE B AND C OF TO POUR 2) LINE 2 E,F AND G OK TO POUR 3) LINE 4 OK TO CLOSE 4) LINE 7 OK TO CLOSE | |
05/12/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) OPEN FORMS FOR INSP AT COLUMNS. 2) RFI ENG ABOUT RANDOM VERTICAL DOWELS UP TO 5" SHORT (72" REQ) "IT IS NECESSARY THAT C.O.T. PERFORM ALL INSP. SPEC INSP IS IN ADDITION TO C.O.T." COLUMNS: LINE 1 B DENIED EXPOXIED DOWEL OUT OF CAGE. C- OK TO CLOSE & POUR. D- DENIED DOWEL OUT OF CAGE. LINE 2 E, F, G- YOU NEED TO PROVIDE 1 1/2" CLEAR TO TIES. OK TO CLOSE I NEED TO REINSP CLEARANCES BEFORE YOU POUR. |