Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 07/15/2004 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection :* |
| 07/07/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) CORRECT DRAINAGE AT KITCHEN SINK, RUN 2" ARM FROM BARREL OF FIXUTRE WITH 2" TRAP OR PROVIDE 1 1/2 ARM ALL THE WAY FROM BARREL OF FITTING. RE-TEST AND CALL BACK IN 2) INSTALL H2O PIPING PER SIZING ON APPROVED REVISED PLAN |
| 06/30/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) H2O PIPING TO BE TESTED AND INSTALLED PER PLAN OR PROVIDE CITY APPROVED PLAN OF YOUR INSTALLATION. 2) PROVIDE FIRE CAULKING PER PLAN. 3) PROVIDE CORRECT C.O. AT KITCHEN SINK AND CORRECT DRAINAGE ARM. 15 PSI AIR TEST FROM METER LOCATION ON BOTH 1" GAS LINES TO ROOF TOP UNIT AND STOVE ONLY AT THIS TIME. WTR HTR GAS PIPING TO BE INSTALLLED AND RETESTED USING 15 PSI GUAGE. |