Permit: T03CM04972

Parcel: 11611005H


Addresses:

2800 W BROADWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
03/24/2005 PLUMBING - INTERMEDIATE Approved 1) URINAL ADDED TO PLAN
2) OK TO COVER
03/23/2005 PLUMBING - INTERMEDIATE Cancelled IVRS - AP canceled
03/22/2005 PLUMBING - INTERMEDIATE Partial Approval 1) JOBSITE TRAILER HAS BEEN REMOVED. UNABLE TO LOCATE PLAN OR PERMIT. 2) IS THE URINAL BEING RE-INSTALLED ? IF SO, HAVE YOUR PLUMBER TAKE A SECOND LOOK AT HIS WORK.
03/21/2005 PLUMBING - INTERMEDIATE Cancelled IVRS - AP canceled
02/10/2005 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*1) OK TO COVER ALL AREAS. 2) WATER SERVICE OK TO VALVE. 3) WILL NEED TO SEE YARDWATER FOR CABANA 4) NOTE NO INSPECTIONS HAVE BEEN MADE AT POOL EQUIPTMENT PVC UNDERSLAB NOT APPROVED?
02/09/2005 PLUMBING - INTERMEDIATE Approved 1) PVC DWV THRU ROOF OK. COPPER OK W/EXCEPTION: JOINTS UNDER SLAB TO BE SIL FUS'D. 2) OK TO COVER WALLS. 3) PVC WATER SERVICE DOES NOT HAVE ADEQUETE FILL NOT ADEQUETE PROTECTION AGAINST DAMAGE
02/07/2005 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :* 1) PLAN SHOWS 12.56 INC SQ AREA OF VENTING, YOU HAVE PROVIDED 10.14 IN SQ AREA BECAUSE YOU DIDN'T FOLLOW THE PLAN. 2) UNABLE TO LOCATE PERMIT. 3) REMOVE AND REPLACE ALL BURNT FITTINGS AND VALVES AND INSTALL IN A WORKMAN SHIP LIKE MANNER.
01/31/2005 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
01/28/2005 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :* INSTALL PER YOUR APPROVED PLAN
01/26/2005 PLUMBING - INTERMEDIATE Not ready for Inspection 1) HAVE INSPECTIONS FOR CABANA AND MAIL KIOSK SWITCHED. CALL FOR ROUGH/SOIL AND HAVE INSPECTION RESULTS FROM CLUBHOUSE AVAILABLE. 2) NOT INSTALLED PER PLAN. AGGREGATE CROSS SECTIONAL AREA OF VENTING TO BE AT LEAST THAT OF THE LARGEST BUILDING SEWER ( 7.012") PLAN CALLS FOR 12.56"2 YOU HAVE 6.28"2. 3) URINAL NOT ON PLAN.