Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/28/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/23/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) SECURE HOLDOWNS AT GARAGE WALL 2) PROVIDE FIXES AT TRUSS PLATES 3) NAIL PORCH LEDGER 4) NAIL PLATE 220 IN GARAGE |
| 01/14/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PLANS DO NOT MATCH AS BUILT 2) PROVIDE ENGINEERED FIX FOR TRUSSES WITH MISPLACED PLATES 3) GRADE STAMP TRUSSES 4) NO TESTS |