Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/28/2004 FRAMING Approved IVRS - Inspection 0000*
01/23/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) SECURE HOLDOWNS AT GARAGE WALL 2) PROVIDE FIXES AT TRUSS PLATES 3) NAIL PORCH LEDGER 4) NAIL PLATE 220 IN GARAGE