Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/29/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/27/2004 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) NO WATER TEST |
| 01/26/2004 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) NO DWV WATERTEST 2) NO HALL BATH W/C FLOOR FLANGE 3) ATTIC ACCESS BLOCKED BY GAS LINE |
| 01/23/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) INSTALL A35'S AT GARAGE DRAG STRUT PER DETAIL 8, A8 2) BLOCK AND NAIL OSB AT GARAGE WALL PER DETAIL 3) INSTALL DETAIL 3, A8B 4) INSTALL DETAIL 7, A8A 5) INSTALL HANGER AT CENTER TRUSS IN GARAGE AT DUTCH 6) NAIL TRIMMERS PER DETAIL 1, A8A 7) FIRE STOP GARAGE PLATFORM 8) SHIM 3 PT TRUSSES AT BEARING 9) THE LETTER FROM THE TRUSS MFG MUST BE SUBMITTED TO CITY OF TUCSON FOR APPROVAL 10) STOPPED-TOO MANY ITEMS |
| 01/14/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) REMOVE INSULATION |