Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM04958

Parcel: 138242440

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/29/2004 FRAMING Approved IVRS - Inspection 0000*
01/27/2004 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) NO WATER TEST
01/26/2004 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) NO DWV WATERTEST 2) NO HALL BATH W/C FLOOR FLANGE 3) ATTIC ACCESS BLOCKED BY GAS LINE
01/23/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) INSTALL A35'S AT GARAGE DRAG STRUT PER DETAIL 8, A8 2) BLOCK AND NAIL OSB AT GARAGE WALL PER DETAIL 3) INSTALL DETAIL 3, A8B 4) INSTALL DETAIL 7, A8A 5) INSTALL HANGER AT CENTER TRUSS IN GARAGE AT DUTCH 6) NAIL TRIMMERS PER DETAIL 1, A8A 7) FIRE STOP GARAGE PLATFORM 8) SHIM 3 PT TRUSSES AT BEARING 9) THE LETTER FROM THE TRUSS MFG MUST BE SUBMITTED TO CITY OF TUCSON FOR APPROVAL 10) STOPPED-TOO MANY ITEMS
01/14/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) REMOVE INSULATION