Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
Permit Number - T03CM04925
Inspection Description - MECHANICAL - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/11/2004 | MECHANICAL - INTERMEDIATE | Approved | ||
02/25/2004 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1) SUSPENDED ROUGH DUCT ONLY. NOTE: DRYER DUCT (PROJECTED) NEEDS TO BE SMOOTH WALL 4" OR OVAL CONNECTOR PIPE. NO FLEX ALLOWED EXCEPT SMALL PE. OUT OF DRYER TO CONNECT TO RIDGID VENT 2) WHERE IS 1" CU (COPPER) CONDENSATE LINE ? IN WALL ? 3) EXHAUST DUCTS LOCATED IN RETRUN AIR PLENIUMS NEED TO BE RIGID SHT. MTL PIPE WITH SEALED JOINTS. NO PORTIONS OF FLEXABLE DUCT |