Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T03CM04925
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/15/2004 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*/ 1) ARCHITECT TO BE AWARE OF CLEAN-OUT AT SHAMPOO BOWL NOT FLUSH WITH WALL. 2) PLBG FINAL OK. 3) OK FOR C OF O PENDING ANY OTHER INSP. | |
03/12/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*/ 1) CLEAN OUT REQUIRES 12" CLEARANCE IN FRONT. NOTE: HORIZONTAL C.O. EXTENSION SHALL BE THRU A WYE BRANCH FITTING, NOT A SANTEE. 2) HAVE THE PLBR RE-READ PLBG NOTE #4 AND THEN STAND IN FRONT OF THE WTR HTR. MAKE NECESSARY CORRECTION. | |
03/10/2004 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection 0000*/ 1) POST YOUR ADDRESS!!! 2) HAVE PLBR READ PLBG NOTES MP-1 ESPECIALLY #4&5. 3) WHERE IS THE W.C.O. AT SHAMPOO BOWL. 4) INSPECTION STOPPED. |