Permit: T03CM04922

Parcel: 138142500

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
05/10/2004 BUILDING - FINAL Approved IVRS - Inspection :*
03/12/2004 BUILDING - FINAL Denied IVRS - Inspection 0999* EXPOSE ALL PLUMBING FOR INSECTION. SHAVOR REQUIRES ANTI SCALD CONTROL VALVES. LAUNDRY NOT PROPERLY VENTED. WASHER REQUIRES 2" DRAIN LINE. INADEQUATE EGRESS FROM MASTER BEDROOM. PROVIDE PROOF OF ALL FOUNDATION DEPTH AND WIDTH. EXPOSE ALL ELECTRICAL ADDED. EXPOSE ALL MECHANICAL DUCTWORK ADDED. EXPOSE ALL ADDED FRAMING. EXISTING BATHROOM MUST HAVE MECHANICAL VENTILATION. PLAN CALLS FOR 2X10 RIDGE BEAM @ ADDITION. ALL RAFTERS MUST BEAR ON SIMPSON HANGERS. PROVIDE PROOF OF ALL REQUIRED STEEL IN MASONRY WALLS.