Permit: T03CM04908

Parcel: 121120680

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
10/13/2004 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
10/12/2004 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
1) PROTECT CONDUCTORS INSIDE BOXES. 2) FINISH ITEMS # 1, 2, 3, 6, 7.
10/11/2004 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*/1)SUPPORT NM? CABLES ABOVE PANEL & BELOW 2)FINISH #2 PREVIOUS 3)TIGHTEN LOOSE FITTINGS AT EXHAUST FANS & PANELS 4)PROTECT CABLES AT STUDS 5)MAINTAIN WORKING CLEARENCES FOR A/C DISCONNECTS 6)CABLE TO BE SECURED TO PANEL 7)SECURE NM CABLE WITHIN 12" OF EXHAUST FANS
10/08/2004 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :The wiring is not complete or does not comply with code.| USE ROMEX CLAMP TYPE CONNECTORS FOR BATHROOM FANS
TOO MANY CABLE TERMINATION INTO ROMEX CONNECTORS AT PANEL, CHECK LISTING AND INSTALL PER MFG.
ROMEX NOT TERMINATED INTO BOX FOR OUTSIDE LIGHT