Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM04899

Parcel: 11611005H

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/13/2005 PLUMBING - FINAL Approved IVRS - Inspection :* 1) PLUMBING FINAL OK. 2) OK FOR C OF O PENDING ANY OTHER INSPECTION AND SUBJECT TO CERTIFICATION OF PRIVATE SEWER
04/05/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 1) PROVIDE CERTIFICATION FROM DEQ FOR PRIVATE SEWER. 2) PROVIDE DOCUMENTATION ON APPROVAL OF ROOF DRAINS.
04/04/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 1) CAL IN AND HAVE APPROVED ALL REQUIRED INSPECTIONS PRIOR TO CALLING FINAL. 2) POST HOUR HDG NUMBERS. 3) NO NOTICE IN ELECTRIC SERVICE PANEL. 4) A TRAP ARM MAY ONLY CHANGE DIRETION 90 DEGREE WITHOUT ADDING A CLEAN OUT. 5) 1 1/2" & 2" CLEAN OUTS REQUIRE 12" CLEARANCE IN FRONT OF THE CLEAN OUT