Permit: T03CM04898

Parcel: 11624101A

Inspection Status: Approved

Inspection History: BUILDING PRE-SLAB

Date Description Inspector Results Comments
01/30/2004 BUILDING PRE-SLAB Approved IVRS - Inspection 0000*
01/29/2004 BUILDING PRE-SLAB Not ready for Inspection IVRS - Inspection 0000*/ 1) COULD NOT WAIT-RECALL
01/27/2004 BUILDING PRE-SLAB Denied IVRS - Inspection 0999*/ 1) 3' BARS INTO SLAB REQUIRE 2' INTO SOLID GROUT CELLS PER DETAIL. THIS BAR IS IN ADDITION TO THE VERTICALS 2) THE LAPS ARE TOO SHORT ON THE AS BUILT 3) REVISE PLANS AND INSTALL 40 BAR DIAMETER LAPS. TO BE APPROVED BY CITY OF TUCSON PRIOR TO INSPECTION