Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 01/14/2004 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Approved |
IVRS - Inspection 0000* |
| 01/12/2004 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999* 1) SLEEVE CANNOT BE UTILIZED IN THIS MANNER. YOU ARE ONLY ALLOWED TO DISPLACE 4% OF THE CONCRETE THROUGH THE FOOTING. 2) SHORT LAPS AT STEEL NEAR SLEEVE |
| 01/08/2004 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/ 1) REMOVE LOOSE DEBRIS, ROOTS FROM FOOTING 2) REMOVE GAS LINE FROM FOOTING 3) PROTECT SEWER LINE THROUGH FOOTING-SUPPORT AND SLEEVE CLAY 4) MAKE FOOTING STEEL CONTINOUS AT SEWERLINE 5) 3" CLEARANCE AT SOIL TO STEEL 6) 12" MINIMUM HEIGHT ON FORMS |