Permit: T03CM04898

Parcel: 11624101A

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
01/14/2004 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection 0000*
01/12/2004 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection 0999* 1) SLEEVE CANNOT BE UTILIZED IN THIS MANNER. YOU ARE ONLY ALLOWED TO DISPLACE 4% OF THE CONCRETE THROUGH THE FOOTING. 2) SHORT LAPS AT STEEL NEAR SLEEVE
01/08/2004 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection 0999*/ 1) REMOVE LOOSE DEBRIS, ROOTS FROM FOOTING 2) REMOVE GAS LINE FROM FOOTING 3) PROTECT SEWER LINE THROUGH FOOTING-SUPPORT AND SLEEVE CLAY 4) MAKE FOOTING STEEL CONTINOUS AT SEWERLINE 5) 3" CLEARANCE AT SOIL TO STEEL 6) 12" MINIMUM HEIGHT ON FORMS