Permit: T03CM04885

Parcel: 137340010


Addresses:

1650 W VALENCIA RD


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T03CM04885

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
04/27/2004 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :
See detailed listing on site.| 999*/ 1) AIR PRESSURE TEST ON WASTE AND VENT SYSTEM IS OK 2) MUST SEE FINAL CONNECTIONS TO SUMP PUMP AND HOLDING TANK 3) OK FOR BACKFILL AND CONCRETE
04/26/2004 PLUMBING - ROUGH, SOIL Denied 1) MUST PROVIDE DWV PVC SCHEDULE 40 MATERIAL FOR DRAINAGE MATERIAL AND FITTINGS 2) MUST PROVIDE AIR TEST MINIMUM 5 POUNDS AT TIME OF INSPECTION 3) MUST SEAL PENETRATION THRU WALL
04/22/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection 1) NO TEST 2) PROVIDE PROPER TRANSITION FITTINGS INSIDE BLDG FROM PVC-ABS. ALSO PROVIDE APPROVED TRANSITION FITTING BETWEEN PVC AND ABS AT TANK 3) VENT NOT TO CODE