Permit: T03CM04884

Parcel: 133231610


Addresses:

7150 E SPEEDWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T03CM04884

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
06/18/2004 PLUMBING - ROUGH, SOIL Approved
05/07/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*/ 1) TEST ON NEW 4" PVC WASTE LINES FROM TRENCH DRAINS TO SUMP TEST OK
05/06/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection 4" WASTE TO CATCH BASIN FROM TRENCH DRAIN ONLY 2) OK TO COVER FLOOR DRAIN IN TIME STORAGE AREA ONE
05/05/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/ WTR TEST ON NORTH TRENCH DRAIN TO STUB 6" BELOW GROUND FLOOR. WILL REQUIRE AIR OR WTR TEST INTO SUMP AREA. T&P PAN DRAIN TO DAYLIGHT OK. 4" CAP ON DEMO FLOOR DRAIN AND 3" CAP ON DEMO MOP SINK OK. 4" CAP ON NORTH END OF INLET TO OLD SUB-LEVEL SUMP OK. 7 PSI AIR TEST ON SUB LEVEL SUMP TANK VENT THRU ROOF OK. 7 PSI AIR TEST ON SUB LEVEL SUMP TANK LINE TO 650 GAL. STORAE TANK OK. NEED WTR TEST ON SUMP TANK SEALS ON PIPING.
05/04/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
05/03/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/ 1) 7 PSI AIR TEST FOR SUMP PUMP VENT THRU ROOF FROM FLOOR LEVEL IN PIT OK. 7 PSI AIR TEST ON SUMP PUMP LINE TO 650 GAL STORAGE TANK FROM FLOOR LEVEL IN PIT OK. 7 PSI AIR TEST ON VENT THRU ROOF FOR 650 GAL STORAGE TANK OK 2) SOUTH TRENCH DRAIN REQUIRES APPROVED COUPLING FOR CONNECTION TO PVC PIPE AND POLY PROPLENE AND WATER TEST AND WILL REQUIRE STAMPED LETTER FROM ENGINEER DELETING CATCH BASIN FOR NORTH AND SOUTH TRENCH DRAINS
04/29/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/ WTR TEST ON NORTH TRENCH DRAIN TO EDGE OF EAST ROLL UP DOOR. OK.