Permit: T03CM04859

Parcel: 137055210


Addresses:

1213 W IRVINGTON RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/17/2004 PLUMBING - FINAL Approved IVRS - Inspection :*
08/12/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)SHALL EXPOSE C.O. FOR ALL HAND SINKS.
2)TRAP ARM CAN ONLY HAVE ONE SLIP JOINT
3)SHALL PROVIDE SAFTEY CABLES FOR ALL GAS APPLIANCES W/CASTERS
4)SHALL PROVIDE APPROVED MATERIAL FOR OVERFLOW R.W.C. THAT WILL BE EXOSE. SUPPORT ACCORDINLY.
5)SHALL PROVIDE C.O. FOR END OF LINE C.O. @SOUTH END OF BLDG.
6)SHALL SECURE FAUCET UNDER SINK @ SOUTH END.
7)HAVE ALL FLOOR SINK GRATES INSTALLED OR ON SITE @ TIME OF INSPECTION
8)INSTALL ADA PIPE & WASTE WRAP
9)PROVIDE ALL IN HOUSE BACKFLOW PREVENTER TEST & CECTIFACTION @TIME OF INSPECTION
08/07/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) WILL REQUIRE 007 BACKFLOW PREVENTER ON ALL ICE MAKERS, COFFEE MACHINE, TEA DISPENSOR, ETC...