Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T03CM04859
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/19/2004 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000* | |
04/16/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999*/ NO TEST ON SYSTEM. | |
04/15/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*/ 1) SOIL WTR TEST IS OK. 2) THIS INSP. IS FOR SOUTH SIDE OF BLDG AS NOTED ON PLAN. 3) NORHT SIDE OF BLDG IS OK. 4) OK TO BACKFILL TRENCH. | |
04/14/2004 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection 0000* | |
04/12/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999*/ 1) MUST REDUCE TAIL PC BY 2 PIPE SIZES AT TOP OF WEIR OF TRAP FOR COMBO WASTE AND VENT. 2) MUST PROVIDE UPPER TERMINAL VENT FOR COMBO WASTE AND VENT SYSTEM. 3) CAN NOT USE DBC COMBO FOR TRAP ARMS. 4) CAN ONLY FLAT VENT SYSTEM DUE TO STRUCTURE CONDITION. |