Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/20/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 02/17/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0935*/ 1) HOUSE INSULATED BEFORE INTERMEDIATE APPROVALS-REMOVE INSULATION 2) NOTHING DONE FROM LAST INSPECTION 3) DRYWALL STOCKED, DRYWALL MUST BE LAYED FLAT |
| 02/12/2004 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) CANCELLED ON SITE BY WILL SUPER |
| 02/06/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NOTHING DONE FROM LAST INSPECTION |
| 02/05/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) BIRD BOARDS MISSING AT BACK PATIO 2) REPAIR SHEAR BLOCKS AND PANELS 3) ABOVE WATER HEATER AREA 4) NAIL PROTECT ELECTRIC AS PER PLAN 5) NO WATER TEST ON DWV'S 6) 8 FEET BRACE CUT AT SOUTH WEST BEDROOM MUST BE PER DETAIL 7SD3 7) FIRE BLOCK AREAS MARKED WALKED WITH MR. SALDANA |