Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/10/2004 |
FRAMING |
|
Approved |
IVRS - Inspection :* |
| 06/08/2004 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) DUCTS THRU ROOF EXHAUST FANS 2) BLOCK ALL MECH 3) BANG PLATE REAR BATH PIPES 4) 12" CLEAR PEX TO LIGHT CAN 5) BACKING WALLS AND CEILING 6) A. BOLTS REAR EAST, SOUTH 7) CAP 2" DRAIN OLD KITCHEN 8) PROTECT ROMEX BED DOOR 9) FIRE BLOCK KITCHEN BATH PLUMBING WALL 10) BUILD PONY WALLS UP TO SCISSOR TRUSSES 11) OVEN VENT THRU ROOF 12) WATER HEATER COMB/RELIEF DUCT AND FLUE 13) DWV AND POTABLE WATER TEST OK |